Commercial, VW, Transporter (SH, SJ) 2019-, 2020 (L), Diesel LDOHC, 800B - Auxiliary air heater 2 (800B AH2)

Heater - 800B - Auxiliary air heater 2 (800B AH2) - 0

Identification

ASAM/ODX file identification: EV_LSHECCSMNB

ASAM/ODX file version: 001001

Part number: xxxxxxxxx

Equipment number: 0

Importer number: 0

Workshop code: 0

VIN no: xxxxxxxxxxxxxxxxx

Software version: xxxx

Hardware part number: xxxxxxxxx

System designation: xxxxxxxxxxxx

Hardware version: xxx

Programmability: Programmable

Program consistency: Program present

System abbreviation: xxxx

Engine: CJTA

Advanced identification

ASAM/ODX file identification: EV_LSHECCSMNB

ASAM/ODX file version: 001001

Software version: xxxx

Engine: CJTA

Programmability status: error in flash memory: No

Programmability status: flash memory faulty: No

Programmability status: communication error: No

Programmability status: flash memory not programmable: No

Number of programming attempts: data block 0: 12336

Number of programming attempts: data block 1: 12336

Number of programming attempts: data block 2: 12336

Number of programming attempts: data block 3: 12336

Number of programming attempts: data block 4: 12336

Number of programming attempts: data block 5: 12336

Number of programming attempts: data block 6: 12336

Number of programming attempts: data block 7: 12336

Number of programming attempts: data block 8: 12336

Number of programming attempts: data block 9: 12336

Number of successful programming attempts: data block 0: 12336

Number of successful programming attempts: data block 1: 12336

Number of successful programming attempts: data block 2: 12336

Number of successful programming attempts: data block 3: 12336

Number of successful programming attempts: data block 4: 12336

Number of successful programming attempts: data block 5: 12336

Number of successful programming attempts: data block 6: 12336

Number of successful programming attempts: data block 7: 12336

Number of successful programming attempts: data block 8: 12336

Number of successful programming attempts: data block 9: 12336

Number of parameterization attempts: data record 0: 12336

Number of parameterization attempts: data record 1: 12336

Number of parameterization attempts: data record 2: 12336

Number of parameterization attempts: data record 3: 12336

Number of parameterization attempts: data record 4: 12336

Number of parameterization attempts: data record 5: 12336

Number of parameterization attempts: data record 6: 12336

Number of parameterization attempts: data record 7: 12336

Number of parameterization attempts: data record 8: 12336

Number of parameterization attempts: data record 9: 12336

Number of successful parameterization attempts: data record 0: 12336

Number of successful parameterization attempts: data record 1: 12336

Number of successful parameterization attempts: data record 2: 12336

Number of successful parameterization attempts: data record 3: 12336

Number of successful parameterization attempts: data record 4: 12336

Number of successful parameterization attempts: data record 5: 12336

Number of successful parameterization attempts: data record 6: 12336

Number of successful parameterization attempts: data record 7: 12336

Number of successful parameterization attempts: data record 8: 12336

Number of successful parameterization attempts: data record 9: 12336

Maximum number of possible update programming: data block 0: 12336

Maximum number of possible update programming: data block 1: 12336

Maximum number of possible update programming: data block 2: 12336

Maximum number of possible update programming: data block 3: 12336

Maximum number of possible update programming: data block 4: 12336

Maximum number of possible update programming: data block 5: 12336

Maximum number of possible update programming: data block 6: 12336

Maximum number of possible update programming: data block 7: 12336

Maximum number of possible update programming: data block 8: 12336

Maximum number of possible update programming: data block 9: 12336

Last update programming of SW module: software module 0, date: 2000-00-00

Last update programming of SW module: software module 0, device number: 0

Last update programming of SW module: software module 0, importer number: 0

Last update programming of SW module: software module 0, dealership number: 0

Last update programming of SW module: software module 0, programming status: Valid

Last update programming of SW module: software module 1, date: 2000-00-00

Last update programming of SW module: software module 1, device number: 0

Last update programming of SW module: software module 1, importer number: 0

Last update programming of SW module: software module 1, dealership number: 0

Last update programming of SW module: software module 1, programming status: Valid

Last update programming of SW module: software module 2, date: 2000-00-00

Last update programming of SW module: software module 2, device number: 0

Last update programming of SW module: software module 2, importer number: 0

Last update programming of SW module: software module 2, dealership number: 0

Last update programming of SW module: software module 2, programming status: Valid

Equipment number: 0

Importer number: 0

Workshop code: 0

FAZIT identification: manufacture location index: SME-RBG

FAZIT identification: day of manufacture: 08.01.10

FAZIT identification: manufacturer test stand number: 0393

FAZIT identification: running manufacturer number: 0079

Manufacturer modification status: control module family: -

Manufacturer modification status: decoration variant: -

Manufacturer modification status: construction version: ---

Manufacturer modification status: manufacture version: ---

Identification of standard software: standard software module 0: High Speed network management

Identification of standard software: standard software module 0, primary version number: 01

Identification of standard software: standard software module 0, secondary version number: 06

Identification of standard software: standard software module 0, revision number: 00

Diagnostic mode: VW diagnostic

Adaptation workshop code: device number: 0

Adaptation workshop code: importer number: 0

Adaptation workshop code: dealership number: 0

Hardware part number: xxxxxxxxx

Hardware version: xxx

Versions of software module: data block 0: 0007

Versions of software module: data block 1: 0003

Versions of software module: data block 2: 0005

Part number: xxxxxxxxx

System designation: xxxxxxxxxxxx

System abbreviation: xxxx

Programmability status: programmability: Programmable

Programmability status: program consistency: Program present

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Read DTC (Normal mode)

Controls

Clear DTC

Read DTC (Agressive mode)

Controls

Clear DTC

Data stream

Security access: number of invalid keys, counter: 0

Standard - ambient data 1: hours: 3

Standard - ambient data 1: day: 24

Standard - ambient data 1: minutes: 0

Standard - ambient data 1: seconds: 48

Standard - ambient data 1: unlearning counter: 48

Standard - ambient data 1: odometer reading: 3158064 km

Standard - ambient data 1: year: 2012

Standard - ambient data 1: month: 0

Control module switch-off, counter: ECU: --

Heating time limitation: activation function heating timeout: Not active

Heating time limitation: heater unlocked, customer service: Not active

Heating time limitation: maximum heating time: 48 min

Heating time limitation: remaining running time: 48 min

Heating time limitation: vehicle speed: 123.36 km/h

Heating time limitation: distance traveled: 12336 m

Overheating counter: 77

Malfunction counter: 111

Cold heating (EMV-Mode): Off

System info CAN: SI_QRS_Mode: Mode not active

System info CAN: SI_T_Schutz: Mode not active

System info CAN: SI_NWDF: Released

System info CAN: SI_BUS_01: CAN active

Terminal info CAN: BS3_Klemme_S: Off

Terminal info CAN: BS3_Klemme_15: Off

Terminal info CAN: BS3_Klemme_50: Off

Terminal info CAN: M10_MotorStopp: Off

Terminal info CAN: M10_Wiederstart: On

E85 level CAN: 840 %

Air pressure CAN: 1034.00 mbar

CAN error bits: motor_12_alt: Signal not active

CAN error bits: clima_sensor_02_alt: Signal not active

CAN error bits: uhrzeit_01_alt: Signal not active

CAN error bits: combi_02_alt: Signal not active

CAN error bits: ESP_21_alt: Signal active

Fuel warning CAN: KBI_Tankwarnung: Off

Fuel warning CAN: KBI_Inhalt_Tank: 48 L

Clima signals CAN: KL_Zuheizer: Off

BEM turn on prohibition CAN: Off

BEM turn off step CAN:

Crash signal CAN:

Target time programming CAN: KL_ZZ_month: 48

Target time programming CAN: KL_ZZ_day: 48

Target time programming CAN: KL_ZZ_hour: 48

Target time programming CAN: KL_ZZ_minute: 48 min

Target time programming CAN: KL_ZZ_status_timer: Signal not active

Target time programming CAN: KL_ZZ_operating_mode:

LSH signals CAN: LSH LED: Signal not active

LSH signals CAN: LSH radio on: Signal active

LSH signals CAN: LSH radio off: Signal not active

LSH signals CAN: LSH service mode: Signal not active

LSH signals CAN: LSH KD error: Signal not active

LSH signals CAN: LSH KVS overflow: Signal active

LSH signals CAN: LSH shut-off stage: Signal active

LSH signals CAN: LSH transport mode: Signal not active

LSH signals CAN: LSH heat input: 48 min

LSH signals CAN: STH heat output: 960 W

LSH signals CAN: LSH heat output: 960 W

LSH signals CAN: LSH error status: No error

LSH signals CAN: LSH text:

Internal function state: operating mode:

Internal function state: operating state:

Internal function state: sequence number start: 48

Internal function state: sequence number followup: 48

Development data on CAN: Not active

Data record: 00000000000000

Battery - charge condition:

Undervoltage threshold constant value: 4.8 V

Undervoltage mode: Constant value

Operating mode:

Combustion air blower: 4800 1/min

Heater glow plug: activation: 48 W

Metering pump: 4.8 Hz

Switch-on conditions for auxiliary heater: terminal 15: Not active

Switch-on conditions for auxiliary heater: A/C request, auxiliary heat mode: Not active

Switch-on conditions for auxiliary heater: engine running status: Not recognized

Switch-on conditions for auxiliary heater: outside air temperature: Ok

Switch-on conditions for auxiliary heater: transport mode: Active

Switch-on conditions for auxiliary heater: static current measuring mode: Not active

Switch-on conditions for auxiliary heater: heater unit locked: Not locked

Switch-on conditions for auxiliary heater: fault that prevents starting: Not active

Switch-on conditions for auxiliary heater: start of operations: Not recognized

Switch-on conditions for auxiliary heater: auxiliary heat.: Not supported

Reasons for auxil. heat inhibit: actuation inhibited by energy management: Not active

Reasons for auxil. heat inhibit: switch-off due to energy management: Not active

Reasons for auxil. heat inhibit: internal undervoltage: Not recognized

Reasons for auxil. heat inhibit: generator failure: Not active

Reasons for auxil. heat inhibit: battery malfunction: Active

Reasons for auxil. heat inhibit: ethanol content in fuel: Ok

Reasons for auxil. heat inhibit: fuel level: Ok

Reasons for auxil. heat inhibit: vehicle elec. system overload: Not active

Reasons for auxil. heat inhibit: heating timeout: Not active

Actuation conditions for auxiliary heater: A/C request, parking heat mode: Not active

Actuation conditions for auxiliary heater: transport mode: Not active

Actuation conditions for auxiliary heater: static current measuring mode: Not active

Actuation conditions for auxiliary heater: heater unit locked: Locked

Actuation conditions for auxiliary heater: fault that prevents starting: Active

Actuation conditions for auxiliary heater: start of operations: Not recognized

Actuation conditions for auxiliary heater: parking heat: Not supported

Reasons for parking heat inhibit: actuation inhibited by energy management: Not active

Reasons for parking heat inhibit: switch-off due to energy management: Not active

Reasons for parking heat inhibit: internal undervoltage: Not recognized

Reasons for parking heat inhibit: generator failure: Not active

Reasons for parking heat inhibit: battery malfunction: Active

Reasons for parking heat inhibit: ethanol content in fuel: Ok

Reasons for parking heat inhibit: fuel level: Ok

Reasons for parking heat inhibit: vehicle elec. system overload: Not active

Reasons for parking heat inhibit: heating timeout: Not active

Auxiliary/parking heater functions: auxiliary heating: Not possible

Auxiliary/parking heater functions: parking heating: Not possible

Auxiliary/parking heater functions: ventilation: Not possible

Ambient temperature: outside air temperature raw value (unfiltered): -26.0 °C

Ambient temperature: -26.0 °C

Ambient temperature: value used: -26.0 °C

Ambient temperature: status: Filtered

Ambient temperature: vehicle speed: 123.36 km/h

Remote control: RF transmitter signal:

Remote control: receiver status:

Remote control: quality of signal last received: 48

Heater operating data: actuation counter, auxiliary heater: 12336

Heater operating data: fuel consumption: 808464432 ml

Heater operating data: burn time: 12336 hours

Heater operating data: burn time: 48 min

Heater operating data: activation duration: 12336 hours

Heater operating data: 48 min

Heater operating data: actuation counter, parking heater: 12336

System runtime in current combustion mode: operating time: 48 min

System runtime in current combustion mode: activation duration: 48 min

System runtime in current combustion mode: remaining running time: 48 min

System runtime in current combustion mode: timer for minimum burn time: 12336 sec

Cut-off requirements, last:

Cut-off requirements, second to last:

Cut-off requirements, third to last:

Cut-off requirements, fourth to last:

First-time operation status: fuel line filling: Not performed

First-time operation status: system test: Not performed

First-time operation status: timer for fuel line filling: 48 sec

Flame generation: Not recognized

Heater unit, reason locked:

Fuel tank level: 48 L

Parking heater - actuation signal:

Radio-frequency transmitter: ID sensor 3: 30 30 30

Radio-frequency transmitter: ID sensor 4: 30 30 30

Radio-frequency transmitter: number of transmitters adapted: 48

Radio-frequency transmitter: ID sensor 1: 30 30 30

Radio-frequency transmitter: ID sensor 2: 30 30 30

RF transmitter - adapting:

Heater - fuel type:

Heater fuel type: engine fuel type:

Heater fuel type: type of fuel: Does not match

Reason for blocking remote control: actuation inhibited by energy management: Not active

Reason for blocking remote control: switch-off due to energy management: Not active

Reason for blocking remote control: internal undervoltage: Not recognized

Reason for blocking remote control: ethanol content in fuel: Limiting values exceeded

Reason for blocking remote control: fuel level: Fuel supply low

Reason for blocking remote control: heating timeout: Not active

Air distribution flap motor: target value: rear

Air distribution flap motor: rear

Air distribution flap motor: direction of movement: Not active

Air distribution flap motor: actuation time: 4.8 sec

Air distribution flap motor: displacement time for flap limit stop, rear - front: 4.8 sec

Air distribution flap motor: displacement time for flap limit stop, front - rear: 4.8 sec

Air distribution flap motor: adapting: Adapted

Air distribution flap motor: activation current: 480 mA

Status of temperature sensors: auxiliary heater air inlet temperature sensor: 3044.00 °C

Status of temperature sensors: auxiliary heater air inlet temperature sensor in the roof: 3044.00 °C

Status of temperature sensors: auxiliary heater air outlet temperature sensor: 3044.00 °C

Status of temperature sensors: activation: Auxiliary heater air inlet temperature sensor

Heating levels: heating level, A/C operating unit: Stage 1

Heating levels: heating level, air parking heater: Stage 4

Engine speed: 12336 1/min

Parking heater - operating condition: operating condition:

Parking heater - operating condition: heater output: 48 %

Battery voltage: 4.8 V

Flame monitor: temperature: 1193.6 °C

Actuators test

Controls

Combustion air blower

Heater glow plug

Metering pump

Air distribution flap motor

Basic setting

Controls

Resetting of all adaptations

Adapting RF transmitter

Heater operation for production

Heating shut off

Heater unlock

Adapting RF transmitter via barcode

Fuel line filling

Heater operation for customer service

Unlock heating device

Air distribution flap motor

Utility

Controls

Note request for auxiliary heater from A/C system

Activation of simulated flamme run for EMV measuring

Evaluate air pressure via CAN

Initial fuel filling

Insufficient voltage threshold

Low voltage detection, time limit

Development data on CAN

Heating levels

Evaluate ethanol content

Auxiliary heater air inlet temperature sensor

Auxiliary heater air inlet temperature sensor in the roof

Control module switch-off, switch-off time

Heating time limitation

Minimum burn time

Auxiliary heat control parameters

Parking heat control parameters

Air distribution flap motor

Configuration

Controls

Configuration

Manual mode

Controls

SFD

Configuration