Commercial, VW, Transporter (SH, SJ) 2019-, 2020 (L), Diesel LDOHC, 800B - Auxiliary air heater 2 (800B AH2)
Heater - 800B - Auxiliary air heater 2 (800B AH2) - 0
Identification
ASAM/ODX file identification: EV_LSHECCSMNB
ASAM/ODX file version: 001001
Part number: xxxxxxxxx
Equipment number: 0
Importer number: 0
Workshop code: 0
VIN no: xxxxxxxxxxxxxxxxx
Software version: xxxx
Hardware part number: xxxxxxxxx
System designation: xxxxxxxxxxxx
Hardware version: xxx
Programmability: Programmable
Program consistency: Program present
System abbreviation: xxxx
Engine: CJTA
Advanced identification
ASAM/ODX file identification: EV_LSHECCSMNB
ASAM/ODX file version: 001001
Software version: xxxx
Engine: CJTA
Programmability status: error in flash memory: No
Programmability status: flash memory faulty: No
Programmability status: communication error: No
Programmability status: flash memory not programmable: No
Number of programming attempts: data block 0: 12336
Number of programming attempts: data block 1: 12336
Number of programming attempts: data block 2: 12336
Number of programming attempts: data block 3: 12336
Number of programming attempts: data block 4: 12336
Number of programming attempts: data block 5: 12336
Number of programming attempts: data block 6: 12336
Number of programming attempts: data block 7: 12336
Number of programming attempts: data block 8: 12336
Number of programming attempts: data block 9: 12336
Number of successful programming attempts: data block 0: 12336
Number of successful programming attempts: data block 1: 12336
Number of successful programming attempts: data block 2: 12336
Number of successful programming attempts: data block 3: 12336
Number of successful programming attempts: data block 4: 12336
Number of successful programming attempts: data block 5: 12336
Number of successful programming attempts: data block 6: 12336
Number of successful programming attempts: data block 7: 12336
Number of successful programming attempts: data block 8: 12336
Number of successful programming attempts: data block 9: 12336
Number of parameterization attempts: data record 0: 12336
Number of parameterization attempts: data record 1: 12336
Number of parameterization attempts: data record 2: 12336
Number of parameterization attempts: data record 3: 12336
Number of parameterization attempts: data record 4: 12336
Number of parameterization attempts: data record 5: 12336
Number of parameterization attempts: data record 6: 12336
Number of parameterization attempts: data record 7: 12336
Number of parameterization attempts: data record 8: 12336
Number of parameterization attempts: data record 9: 12336
Number of successful parameterization attempts: data record 0: 12336
Number of successful parameterization attempts: data record 1: 12336
Number of successful parameterization attempts: data record 2: 12336
Number of successful parameterization attempts: data record 3: 12336
Number of successful parameterization attempts: data record 4: 12336
Number of successful parameterization attempts: data record 5: 12336
Number of successful parameterization attempts: data record 6: 12336
Number of successful parameterization attempts: data record 7: 12336
Number of successful parameterization attempts: data record 8: 12336
Number of successful parameterization attempts: data record 9: 12336
Maximum number of possible update programming: data block 0: 12336
Maximum number of possible update programming: data block 1: 12336
Maximum number of possible update programming: data block 2: 12336
Maximum number of possible update programming: data block 3: 12336
Maximum number of possible update programming: data block 4: 12336
Maximum number of possible update programming: data block 5: 12336
Maximum number of possible update programming: data block 6: 12336
Maximum number of possible update programming: data block 7: 12336
Maximum number of possible update programming: data block 8: 12336
Maximum number of possible update programming: data block 9: 12336
Last update programming of SW module: software module 0, date: 2000-00-00
Last update programming of SW module: software module 0, device number: 0
Last update programming of SW module: software module 0, importer number: 0
Last update programming of SW module: software module 0, dealership number: 0
Last update programming of SW module: software module 0, programming status: Valid
Last update programming of SW module: software module 1, date: 2000-00-00
Last update programming of SW module: software module 1, device number: 0
Last update programming of SW module: software module 1, importer number: 0
Last update programming of SW module: software module 1, dealership number: 0
Last update programming of SW module: software module 1, programming status: Valid
Last update programming of SW module: software module 2, date: 2000-00-00
Last update programming of SW module: software module 2, device number: 0
Last update programming of SW module: software module 2, importer number: 0
Last update programming of SW module: software module 2, dealership number: 0
Last update programming of SW module: software module 2, programming status: Valid
Equipment number: 0
Importer number: 0
Workshop code: 0
FAZIT identification: manufacture location index: SME-RBG
FAZIT identification: day of manufacture: 08.01.10
FAZIT identification: manufacturer test stand number: 0393
FAZIT identification: running manufacturer number: 0079
Manufacturer modification status: control module family: -
Manufacturer modification status: decoration variant: -
Manufacturer modification status: construction version: ---
Manufacturer modification status: manufacture version: ---
Identification of standard software: standard software module 0: High Speed network management
Identification of standard software: standard software module 0, primary version number: 01
Identification of standard software: standard software module 0, secondary version number: 06
Identification of standard software: standard software module 0, revision number: 00
Diagnostic mode: VW diagnostic
Adaptation workshop code: device number: 0
Adaptation workshop code: importer number: 0
Adaptation workshop code: dealership number: 0
Hardware part number: xxxxxxxxx
Hardware version: xxx
Versions of software module: data block 0: 0007
Versions of software module: data block 1: 0003
Versions of software module: data block 2: 0005
Part number: xxxxxxxxx
System designation: xxxxxxxxxxxx
System abbreviation: xxxx
Programmability status: programmability: Programmable
Programmability status: program consistency: Program present
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Slave systems identification: 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Read DTC (Normal mode)
Controls
Clear DTC
Read DTC (Agressive mode)
Controls
Clear DTC
Data stream
Security access: number of invalid keys, counter: 0
Standard - ambient data 1: hours: 3
Standard - ambient data 1: day: 24
Standard - ambient data 1: minutes: 0
Standard - ambient data 1: seconds: 48
Standard - ambient data 1: unlearning counter: 48
Standard - ambient data 1: odometer reading: 3158064 km
Standard - ambient data 1: year: 2012
Standard - ambient data 1: month: 0
Control module switch-off, counter: ECU: --
Heating time limitation: activation function heating timeout: Not active
Heating time limitation: heater unlocked, customer service: Not active
Heating time limitation: maximum heating time: 48 min
Heating time limitation: remaining running time: 48 min
Heating time limitation: vehicle speed: 123.36 km/h
Heating time limitation: distance traveled: 12336 m
Overheating counter: 77
Malfunction counter: 111
Cold heating (EMV-Mode): Off
System info CAN: SI_QRS_Mode: Mode not active
System info CAN: SI_T_Schutz: Mode not active
System info CAN: SI_NWDF: Released
System info CAN: SI_BUS_01: CAN active
Terminal info CAN: BS3_Klemme_S: Off
Terminal info CAN: BS3_Klemme_15: Off
Terminal info CAN: BS3_Klemme_50: Off
Terminal info CAN: M10_MotorStopp: Off
Terminal info CAN: M10_Wiederstart: On
E85 level CAN: 840 %
Air pressure CAN: 1034.00 mbar
CAN error bits: motor_12_alt: Signal not active
CAN error bits: clima_sensor_02_alt: Signal not active
CAN error bits: uhrzeit_01_alt: Signal not active
CAN error bits: combi_02_alt: Signal not active
CAN error bits: ESP_21_alt: Signal active
Fuel warning CAN: KBI_Tankwarnung: Off
Fuel warning CAN: KBI_Inhalt_Tank: 48 L
Clima signals CAN: KL_Zuheizer: Off
BEM turn on prohibition CAN: Off
BEM turn off step CAN:
Crash signal CAN:
Target time programming CAN: KL_ZZ_month: 48
Target time programming CAN: KL_ZZ_day: 48
Target time programming CAN: KL_ZZ_hour: 48
Target time programming CAN: KL_ZZ_minute: 48 min
Target time programming CAN: KL_ZZ_status_timer: Signal not active
Target time programming CAN: KL_ZZ_operating_mode:
LSH signals CAN: LSH LED: Signal not active
LSH signals CAN: LSH radio on: Signal active
LSH signals CAN: LSH radio off: Signal not active
LSH signals CAN: LSH service mode: Signal not active
LSH signals CAN: LSH KD error: Signal not active
LSH signals CAN: LSH KVS overflow: Signal active
LSH signals CAN: LSH shut-off stage: Signal active
LSH signals CAN: LSH transport mode: Signal not active
LSH signals CAN: LSH heat input: 48 min
LSH signals CAN: STH heat output: 960 W
LSH signals CAN: LSH heat output: 960 W
LSH signals CAN: LSH error status: No error
LSH signals CAN: LSH text:
Internal function state: operating mode:
Internal function state: operating state:
Internal function state: sequence number start: 48
Internal function state: sequence number followup: 48
Development data on CAN: Not active
Data record: 00000000000000
Battery - charge condition:
Undervoltage threshold constant value: 4.8 V
Undervoltage mode: Constant value
Operating mode:
Combustion air blower: 4800 1/min
Heater glow plug: activation: 48 W
Metering pump: 4.8 Hz
Switch-on conditions for auxiliary heater: terminal 15: Not active
Switch-on conditions for auxiliary heater: A/C request, auxiliary heat mode: Not active
Switch-on conditions for auxiliary heater: engine running status: Not recognized
Switch-on conditions for auxiliary heater: outside air temperature: Ok
Switch-on conditions for auxiliary heater: transport mode: Active
Switch-on conditions for auxiliary heater: static current measuring mode: Not active
Switch-on conditions for auxiliary heater: heater unit locked: Not locked
Switch-on conditions for auxiliary heater: fault that prevents starting: Not active
Switch-on conditions for auxiliary heater: start of operations: Not recognized
Switch-on conditions for auxiliary heater: auxiliary heat.: Not supported
Reasons for auxil. heat inhibit: actuation inhibited by energy management: Not active
Reasons for auxil. heat inhibit: switch-off due to energy management: Not active
Reasons for auxil. heat inhibit: internal undervoltage: Not recognized
Reasons for auxil. heat inhibit: generator failure: Not active
Reasons for auxil. heat inhibit: battery malfunction: Active
Reasons for auxil. heat inhibit: ethanol content in fuel: Ok
Reasons for auxil. heat inhibit: fuel level: Ok
Reasons for auxil. heat inhibit: vehicle elec. system overload: Not active
Reasons for auxil. heat inhibit: heating timeout: Not active
Actuation conditions for auxiliary heater: A/C request, parking heat mode: Not active
Actuation conditions for auxiliary heater: transport mode: Not active
Actuation conditions for auxiliary heater: static current measuring mode: Not active
Actuation conditions for auxiliary heater: heater unit locked: Locked
Actuation conditions for auxiliary heater: fault that prevents starting: Active
Actuation conditions for auxiliary heater: start of operations: Not recognized
Actuation conditions for auxiliary heater: parking heat: Not supported
Reasons for parking heat inhibit: actuation inhibited by energy management: Not active
Reasons for parking heat inhibit: switch-off due to energy management: Not active
Reasons for parking heat inhibit: internal undervoltage: Not recognized
Reasons for parking heat inhibit: generator failure: Not active
Reasons for parking heat inhibit: battery malfunction: Active
Reasons for parking heat inhibit: ethanol content in fuel: Ok
Reasons for parking heat inhibit: fuel level: Ok
Reasons for parking heat inhibit: vehicle elec. system overload: Not active
Reasons for parking heat inhibit: heating timeout: Not active
Auxiliary/parking heater functions: auxiliary heating: Not possible
Auxiliary/parking heater functions: parking heating: Not possible
Auxiliary/parking heater functions: ventilation: Not possible
Ambient temperature: outside air temperature raw value (unfiltered): -26.0 °C
Ambient temperature: -26.0 °C
Ambient temperature: value used: -26.0 °C
Ambient temperature: status: Filtered
Ambient temperature: vehicle speed: 123.36 km/h
Remote control: RF transmitter signal:
Remote control: receiver status:
Remote control: quality of signal last received: 48
Heater operating data: actuation counter, auxiliary heater: 12336
Heater operating data: fuel consumption: 808464432 ml
Heater operating data: burn time: 12336 hours
Heater operating data: burn time: 48 min
Heater operating data: activation duration: 12336 hours
Heater operating data: 48 min
Heater operating data: actuation counter, parking heater: 12336
System runtime in current combustion mode: operating time: 48 min
System runtime in current combustion mode: activation duration: 48 min
System runtime in current combustion mode: remaining running time: 48 min
System runtime in current combustion mode: timer for minimum burn time: 12336 sec
Cut-off requirements, last:
Cut-off requirements, second to last:
Cut-off requirements, third to last:
Cut-off requirements, fourth to last:
First-time operation status: fuel line filling: Not performed
First-time operation status: system test: Not performed
First-time operation status: timer for fuel line filling: 48 sec
Flame generation: Not recognized
Heater unit, reason locked:
Fuel tank level: 48 L
Parking heater - actuation signal:
Radio-frequency transmitter: ID sensor 3: 30 30 30
Radio-frequency transmitter: ID sensor 4: 30 30 30
Radio-frequency transmitter: number of transmitters adapted: 48
Radio-frequency transmitter: ID sensor 1: 30 30 30
Radio-frequency transmitter: ID sensor 2: 30 30 30
RF transmitter - adapting:
Heater - fuel type:
Heater fuel type: engine fuel type:
Heater fuel type: type of fuel: Does not match
Reason for blocking remote control: actuation inhibited by energy management: Not active
Reason for blocking remote control: switch-off due to energy management: Not active
Reason for blocking remote control: internal undervoltage: Not recognized
Reason for blocking remote control: ethanol content in fuel: Limiting values exceeded
Reason for blocking remote control: fuel level: Fuel supply low
Reason for blocking remote control: heating timeout: Not active
Air distribution flap motor: target value: rear
Air distribution flap motor: rear
Air distribution flap motor: direction of movement: Not active
Air distribution flap motor: actuation time: 4.8 sec
Air distribution flap motor: displacement time for flap limit stop, rear - front: 4.8 sec
Air distribution flap motor: displacement time for flap limit stop, front - rear: 4.8 sec
Air distribution flap motor: adapting: Adapted
Air distribution flap motor: activation current: 480 mA
Status of temperature sensors: auxiliary heater air inlet temperature sensor: 3044.00 °C
Status of temperature sensors: auxiliary heater air inlet temperature sensor in the roof: 3044.00 °C
Status of temperature sensors: auxiliary heater air outlet temperature sensor: 3044.00 °C
Status of temperature sensors: activation: Auxiliary heater air inlet temperature sensor
Heating levels: heating level, A/C operating unit: Stage 1
Heating levels: heating level, air parking heater: Stage 4
Engine speed: 12336 1/min
Parking heater - operating condition: operating condition:
Parking heater - operating condition: heater output: 48 %
Battery voltage: 4.8 V
Flame monitor: temperature: 1193.6 °C
Actuators test
Controls
Combustion air blower
Heater glow plug
Metering pump
Air distribution flap motor
Basic setting
Controls
Resetting of all adaptations
Adapting RF transmitter
Heater operation for production
Heating shut off
Heater unlock
Adapting RF transmitter via barcode
Fuel line filling
Heater operation for customer service
Unlock heating device
Air distribution flap motor
Utility
Controls
Note request for auxiliary heater from A/C system
Activation of simulated flamme run for EMV measuring
Evaluate air pressure via CAN
Initial fuel filling
Insufficient voltage threshold
Low voltage detection, time limit
Development data on CAN
Heating levels
Evaluate ethanol content
Auxiliary heater air inlet temperature sensor
Auxiliary heater air inlet temperature sensor in the roof
Control module switch-off, switch-off time
Heating time limitation
Minimum burn time
Auxiliary heat control parameters
Parking heat control parameters
Air distribution flap motor
Configuration
Controls
Configuration
Manual mode
Controls
SFD
Configuration